Dermaindia


Microfrxl
Fractional C02 with Microneedle RF

Scanners and Cutting Surgery Heads

Indications

Skin resurfacing (to improve texture)
Pigmented lesions: Age spots / brown spots / Sun spots
Wrinkles around the eyes
Acne scars
Surgical scars
Melasma (mask of pregnancy)
Actinic Keratoses

Technical specification

Laser source : Metal RF Co2 Laser Generator
Laser Type : 10.6 micrometer
Output Power : 40W
Focal length of working head : F=75mm
Indication beam : Red Diode Laser (650nm, <=5mW)
Transmission System : 7-Articulation Joint Spring Arm
Smoke Exhausting System : Built-in air blow
Cooling System : Air cooling
Environmental temperature : 5 deg C ~ 40 deg C
Relative Humidity : <=80%
Power Supply : ~220V +- 22V, 50 Hz +- 1 Hz
Dimension : 38 * 40 * 110 cm
Weight : 40 kg

Working mode

Continuos : Power 1 ~ 40W step adjustable each 1W
Pulse : Power 1 ~ 40W step adjustable each 1
Interval time : 1 ~ 999ms
Ultra pulse : Power 1 ~ 40W step adjustable each 1W, Modulated frequency of 1000Hz
Pulse Duration : 90-1000micro seconds

Scanning mode

Scan mode : Ellipse, Rectangular, Triangular, Line, Square, Hexagon, Round.
Repeat delay : 0.1s to 5.0s
Micro Pulse Energy : 5mJ - 50mJ
Treatment Level : 0.30% to 25%
Passes : 1 to 10 times
Estimated Power : 24mJ to 1000J
Ellipses Estimated Power : 31mj to 1000J
Rectangular Estimated Power : 24mJ to 981J
Treatment area : 0.1*0.1mm to 15*15mm (F=50mm)
Handpiece Velocity : 0.1 to 9cm2/s
Scanning Depth : <=2.0mm


Microneedle RF

Indications

The fractional RF is useful for minimal Invasive
epidermal rejuvenation.
Cures and improves wrinkle & scar
Skin rejuvenation and skin tightening
Minimized PIH using RF energy.

Specification of RF

System type : Mono & Bipolar RF, Bipolar RF
Frequency : 2 MHz
Total RF treatment Level : Upto level 10
Dual Operation mode : Fractional RF Micro-needle, Fractional RF Sub-Lative
Max.Energy : 50W
Disposable Tip : Micro-electrode needle, Micro-electrode tip.
Display : 10.4 inch LCD
Switch : Foot switch
Electrical Requirements : AC/100-240V, 50-60Hz

Specification of RF Tips

Micro needle RF Energy

Energy Source : RF(Radio Frequency)
RF output : Max 50W
RF Electrode : Bipolar / Monopolar
Spot size : 12*12mm (25 pin)
Repetition rate : 1.0,2.0,3.0 sec & manual
Penetration depth : 0.5 to 3mm
Duration time (Emission): 0.1 to 0.9 sec

Scanning mode

Scan mode : Ellipse, Rectangular, Triangular, Line, Square, Hexagon, Round.
Repeat delay : 0.1s to 5.0s
Micro Pulse Energy : 5mJ - 50mJ
Treatment Level : 0.30% to 25%
Passes : 1 to 10 times
Estimated Power : 24mJ to 1000J
Ellipses Estimated Power : 31mj to 1000J
Rectangular Estimated Power : 24mJ to 981J
Treatment area : 0.1*0.1mm to 15*15mm (F=50mm)
Handpiece Velocity : 0.1 to 9cm2/s
Scanning Depth : <=2.0mm

Matrix RF

Energy Source : RF(Radio Frequency)
RF output : Max 50W
RF Electrode : Bipolar
Spot size : 12*12mm (25 pin)
Penetration depth : -
Duration time (Emission): 0.1 to 0.9 sec